2021, Number 3
<< Back Next >>
Revista Cubana de Anestesiología y Reanimación 2021; 20 (3)
Target-controlled infusions and closed-loop systems: expansion limits
Aparicio MAI
Language: Spanish
References: 87
Page: 1-19
PDF size: 468.42 Kb.
ABSTRACT
Introduction:
Manual bolus administration has evolved from volumetric infusion based on standardized pharmacological regimens to target-controlled infusion systems and the most sophisticated closed-loop systems.
Objective:
To describe the technological principles and extended clinical applications of target-controlled infusion and closed-loop systems.
Methods:
A nonsystematic review of the literature was carried out, during September 2020, in scientific databases such as Cochrane Database of Systematic Reviews, Pubmed/Medline, EMBASE, Scopus, Web of Science, EBSCOhost, Science Direct, OVID and the academic search engine Google Scholar.
Development:
The availability and portability of electronic devices with advanced processing capacity at relatively affordable prices, the refinement of machine learning and artificial intelligence applied to medical decisions, as well as the complex technological iterations incorporated into open and closed-loop systems, originally developed in the field of anesthesiology, have enabled their expansion to other specialties and clinical settings so diverse as treatment of diabetes mellitus, administration of antineoplastic drugs, mechanical ventilation, control of hemodynamic variables and antimicrobial therapy in critical patients.
Conclusions:
Target-controlled infusion and closed-loop systems have become mature, safe and viable technologies, applied clinically in multiple nations and settings, with superior performance compared to traditional manual systems.
REFERENCES
Ilyas M, Khaqan A, Iqbal J, Riaz RA. Regulation of hypnosis in Propofol anesthesia administration based on non-linear control strategy. Rev Bras Anestesiol. 2016. http://dx.doi.org/10.1016/j.bjane.2015.08.011
Absalom AR, Glen JB, Zwart GJC, Schnider TW, Struys MMRF. Target-controlled infusion: a mature technology. Anesthesia & Analgesia. 2016. https://doi.org/10.1213/ANE.0000000000001009
Struys MMRF, Smet TD, Glen JB, Vereecke HEM, Absalom AR, Schnider TW. The history of target-controlled infusion. Anesthesia & Analgesia. 2015;122:56-9. https://doi.org/10.1213/ANE.0000000000001008
Kuizenga MH, Vereecke HEM, Struys MMRF. Model-based drug administration: current status of target-controlled infusion and closed-loop control. Curr Opin Anesthesiol. 2016;29:475-81. https://doi.org/10.1097/ACO.0000000000000356
Schnider TW, Minto CF, Struys MMRF, Absalom AR. The safety of target-controlled infusions. Anesthesia & Analgesia. 2016;122(1):79-85. https://doi.org/10.1213/ANE.0000000000001005
Bickford RG. Automatic electroencephalographic control of general anesthesia. EEG Clin Neurophysiol. 1950;2(4):93-6. https://doi.org/10.1016/0013-4694(50)90014-9
Rajkomar A, Dean J, Kohane I. Machine learning in medicine. N Engl J Med. 2019;380(14):1347-58. https://doi.org/10.1056/NEJMra1814259
Pirracchio R, Cohen MJ, Malenica I, Cohen J, Chambaz A, Cannesson M, et al. Big data and targeted machine learning in action to assist medical decision in the ICU. Anaesth Crit Care Pain Med. 2019;38:377-84. https://doi.org/10.1016/j.accpm.2018.09.008
Alexander JC, Joshi GP. Anesthesiology, automation and artificial intelligence. Baylor University Medical Center Proceedings. 2017:3. https://doi.org/10.1080/08998280.2017.1391036
Breton MD, Kanapka LG, Beck RW, Ekhlaspour L, Forlenza GP, Cengiz E, et al. A randomized trial of closed-loop control in children with type 1 diabetes. N Engl J Med. 2020;383(9):836-45. https://doi.org/10.1056/NEJMoa2004736
Tauschmann M, Thabit H, Bally L, Allen JM, Hartnell S, Wilinska ME, et al. Closed-loop insulin delivery in suboptimally controlled type 1 diabetes: a multicentre, 12-week randomised trial. The Lancet. 2018:9. http://dx.doi.org/10.1016/S0140-6736
Ekhlaspour L, Forlenza GP, Chernavvsky D, Maahs DM, Wadwa RP, Deboer MD, et al. Closed loop control in adolescents and children during winter sports: Use of the Tandem Control-IQ AP system. Pediatric Diabetes. 2019;20:759-68. https://doi.org/10.1111/pedi.12867
Mage PL, Ferguson BS, Maliniak D, Ploense KL, Kippin TE, Soh HT. Closed-loop control of circulating drug levels in live animals. Nature Biomedical Engineering. 2017:10. https://doi.org/10.1038/s41551-017-0070
Platen Pv, Pomprapa A, Lachmann B, Leonhardt S. The dawn of physiological closed-loop ventilation. A review. Critical Care. 2020;24(121):11. https://doi.org/10.1186/s13054-020-2810-1
Hundeshagen G, Kramer GC, Marques NR, Salter MG, Koutrouvelis AK, Li H, et al. Closed-loop and decision-assist-guided fluid therapy of human hemorrhage. Critical Care Medicine. 2017:10. https://doi.org/10.1097/CCM.0000000000002593
Rinehart J, Lee S, Saugel B, Joosten A. Automated blood pressure control. Semin Respir Crit Care Med. 2020:12. https://doi.org/10.1055/s-0040-1713083
Carpenter GW, Myers HG, Sherer EA, Evans KA, O'neal DP. Closed-Loop intravenous drug administration using photoplethysmography. IEEE Journal of Translational Engineering in Health and Medicine. 2018;6:8. https://doi.org/10.1109/JTEHM.2018.2879090
Libert N, Chenegros G, Harrois A, Baudry N, Cordurie G, Benosman R, et al. Performance of closed-loop resuscitation of haemorrhagic shock with fluid alone or in combination with norepinephrine: an experimental study. Annals of Intensive Care. 2018;8:10. https://doi.org/10.1186/s13613-018-0436-0
Rinehart J, Joosten A, Ma M, Calderon MD, Cannesson M. Closed-loop vasopressor control: in-silico study of robustness against pharmacodynamic variability. Journal of Clinical Monitoring and Computing. 2019;33:795-802. https://doi.org/10.1007/s10877-018-0234-0
Herrero P, Rawson TM, Philip A, Moore LSP, Holmes AH, Georgiou P. Closed-loop control for precision antimicrobial delivery: an in silico proof-of-concept. IEEE Transactions on Biomedical Engineering. 2017:7. https://doi.org/10.1109/TBME.2017.2787423
Rawson TM, O'Hare D, Herrero P, Sharma S, Moore LSP, Barra Ed, et al. Delivering precision antimicrobial therapy through closed-loop control systems. J Antimicrob Chemother. 2017:9. https://doi.org/10.1093/jac/dkx458
Colin PJ, Jonckheere S, Struys MMRF. Target-Controlled continuous infusion for antibiotic dosing: proof-of-principle in an in-silico vancomycin trial in intensive care unit patients. Clin Pharmacokinet. 2018;15:1435-47. https://doi.org/10.1007/s40262-018-0643-8
Colin P, Ferdinande K, Waele JJD. Target controlled infusion in the ICU: an opportunity to optimize antibiotic therapy. En: Vincent JL, editor. Annual update in intensive care and emergency medicine 2019. ed.: Springer Nature Switzerland AG; 2019. p. 497-506.
Jonckheere S, Neve ND, Verbeke J, Decker KD, Brandt I, Boel A, et al. Target-controlled infusion of cefepime in critically Ill patients. Antimicrobial Agents and Chemotherapy. 2020;64(1):e01552-19. https://doi.org/10.1128/AAC.01552-19
Hannivoort LN, Absalom AR, Struys MMRF. The role of pharmacokinetics and pharmacodynamics in clinical anaesthesia practice. Curr Opin Anesthesiol. 2020;33:483-9. https://doi.org/10.1097/ACO.0000000000000881
Grassin-Delyle S, Couturier R, Abe E, Alvarez JC, Devillier P, Urien S. A Practical tranexamic acid dosing scheme based on population pharmacokinetics in children undergoing cardiac surgery. Anesthesiology. 2013;118(4):853-62. https://doi.org/10.1097/aln.0b013e318283c83a
Grassin-Delyle S, Tremey B, Abe E, Fischler M, Alvarez JC, Devillier P, et al. Population pharmacokinetics of tranexamic acid in adults undergoing cardiac surgery with cardiopulmonary bypass. British Journal of Anaesthesia. 2013;111(6):916-24. https://doi.org/10.1093/bja/aet255
Jia Z, Tian G, Ren Y, Sun Z, Lu W, Hou X. Pharmacokinetic model of unfractionated heparin during and after cardiopulmonary bypass in cardiac surgery. Journal of Translational Medicine. 2015;13(45):11. https://doi.org/10.1186/s12967-015-0404-5
Delavenne X, Ollier E, Chollet S, Sandri F, Lanoisele J, Hodin S, et al. Pharmacokinetic/pharmacodynamic model for unfractionated heparin dosing during cardiopulmonary bypass. British Journal of Anaesthesia. 2017;118(5):705-12]. https://doi.org/10.1093/bja/aex044
Du L, Wenning L, Migoya E, Xu Y, Carvalho B, Brookfield K, et al. Population pharmacokinetic modeling to evaluate standard magnesium sulfate treatments and alternative dosing regimens for women with preeclampsia. The Journal of Clinical Pharmacology. 2018:12. https://doi.org/10.1002/jcph.1328
Kunze E, Lilla N, Stetter C, Ernestus R-I, Westermaier T. Magnesium protects in episodes of critical perfusion after aneurysmal SAH. Translational Neuroscience. 2018;9:98-105. https://doi.org/10.1515/tnsci-2018-0016
Papathanasiou T, Springborg AD, Kongstad KT, Staerk D, Møller K, Taylor BK, et al. High-dose naloxone, an experimental tool uncovering latent sensitisation: pharmacokinetics in humans. British Journal of Anaesthesia. 2019;123(2):e204-e14. https://doi.org/10.1016/j.bja.2018.12.007
Sprinks J, Worcester F, Breedon P, Watts P, Hewson D, Bedforth N. A prototype patient-maintained propofol sedation system using target controlled infusion for primary lower-limb arthroplasty. Journal of Medical Systems. 2019;43:8. https://doi.org/10.1007/s10916-019-1377-3
Udy AA, Dulhunty JM, Roberts JA, Davis JS, Webb SAR, Bellomo R, et al. Association between augmented renal clearance and clinical outcomes in patients receiving ß-lactam antibiotic therapy by continuous or intermittent infusion: a nested cohort study of the BLING-II randomised, placebo-controlled, clinical trial. International Journal of Antimicrobial Agents. 2017:7. http://dx.doi.org/10.1016/j.ijantimicag.2016.12.022
Crass RL, Williams P, Roberts JA. The challenge of quantifying and managing pharmacokinetic variability of beta-lactams in the critically ill. Anaesth Crit Care Pain Med. 2020;39:27-9. https://doi.org/10.1016/j.accpm.2019.12.008
Boidin C, Moshiri P, Dahyot-Fizelier C, Goutelle S, Lefeuvre S. Pharmacokinetic variability of beta-lactams in critically ill patients: A narrative review. Anaesth Crit Care Pain Med. 2020;39:87-109. https://doi.org/10.1016/j.accpm.2019.07.016
Jamal JA, Roger C, Roberts JA. Understanding the impact of pathophysiological alterations during critical illness on drug pharmacokinetics. Anaesth Crit Care Pain Med. 2018;37:515-7. https://doi.org/10.1016/j.accpm.2018.10.006
Burton FM, Lowe DJ, Millar J, Corfield AR, Sim MAB. A study protocol for a feasibility study: Propofol target-controlled infusion in emergency department sedation (ProTEDS). A multicentre feasibility study protocol. Pilot and Feasibility Studies. 2019;5(27):8. https://doi.org/10.1186/s40814-019-0412-y
Burton FM, Lowe DJ, Millar JE, Corfield AR, Watson MJ, Shaw M, et al. Effect of target-controlled propofol infusion to reduce the incidence of adverse events for procedural sedation in the emergency department: a systematic review. European Journal of Emergency Medicine. 2019:8. https://doi.org/10.1097/MEJ.0000000000000655
Yousefi M, Heusden Kv, West N, Mitchell IM, Ansermino JM, Dumont GA. A formalized safety system for closed-loop anesthesia with pharmacokinetic and pharmacodynamic constraints. Control Engineering Practice. 2019;84:23-31. https://doi.org/10.1016/j.conengprac.2018.11.009
Tucker GT. Personalized Drug Dosage. Closing the Loop. Pharm Res. 2016:5. https://doi.org/10.1007/s11095-016-2076-0
Cortegiani A, Pavan A, Azzeri F, Accurso G, Vitale F, Gregoretti C. Precision and bias of target-controlled prolonged propofol infusion for general anesthesia and sedation in neurosurgical patients. The Journal of Clinical Pharmacology. 2018:7. https://doi.org/10.1002/jcph.1060
Liu Y, Li M, Yang D, Zhang X, Wu A, Yao S, et al. Closed-Loop control better than open-loop control of profofol TCI guided by BIS: A randomized, controlled, multicenter clinical trial to evaluate the CONCERT-CL Closed- Loop System. PLoS ONE. 2015;10(4):12. https://doi.org/10.1371/journal.pone.0123862
Savoca A, Heusden Kv, Manca D, Ansermino JM, Dumont GA. The effect of cardiac output on the pharmacokinetics and pharmacodynamics of propofol during closed-loop induction of anesthesia. Computer Methods and Programs in Biomedicine. 2020:24. https://doi.org/10.1016/j.cmpb.2020.105406
Loeb RG, Cannesson M. Closed-Loop Anesthesia: Ready for Prime Time? Anesthesia & Analgesia. 2017;124(2):381-2. https://doi.org/10.1213/ANE.0000000000001640
Cotoia A, Mirabella L, Beck R, Matrella P, Assenzo V, Chazot T, et al. Effects of closed-loop intravenous anesthesia guided by bispectral index in adult patients on emergence delirium: a randomized controlled study. Minerva Anestesiologica. 2018;84(4):437-46. https://doi.org/10.23736/S0375-9393.17.11915-2
West N, Heusden Kv, Görges M, Brodie S, Rollinson A, Petersen CL, et al. Design and evaluation of a closed-loop anesthesia system with robust control and safety system. Anesthesia & Analgesia. 2017:12. https://doi.org/10.1213/ANE.0000000000002663
Parvinian B, Pathmanathan P, Daluwatte C, Yaghouby F, Gray iA, Weininger S, et al. Credibility evidence for computational patient models used in the development of physiological closed-loop controlled devices for critical care medicine. Front Physiol. 2019;10:18. https://doi.org/10.3389/fphys.2019.00220
Coeckelenbergh S, Zaouter C, Alexander B, Cannesson M, Rinehart J, Duranteau J, et al. Automated systems for perioperative goal-directed hemodynamic therapy. Journal of Anesthesia. 2019:11. https://doi.org/10.1007/s00540-019-02683-9
Cannesson M. From invention to innovation: bringing perioperative physiological closed-loop systems to the bedside. Anesthesia & Analgesia. 2018;126(6):1812-3. https://doi.org/10.1213/ANE.0000000000002459
Parvinian B, Scully C, Wiyor H, Kumar A, Weininger S. Regulatory considerations for physiological closed- loop controlled medical devices used for automated critical care: food and drug administration workshop discussion topics. Anesthesia & Analgesia. 2017:10. https://doi.org/10.1213/ANE.0000000000002329
Joosten A, Delaporte A, Cannesson M, Rinehart J, Dewilde JP, Obbergh LV, et al. Fully automated anesthesia and fluid management using multiple physiologic closed-loop systems in a patient undergoing high-risk surgery. Anesthesia & Analgesia. 2016:7. https://doi.org/10.1213/XAA.0000000000000405
Gorges M, Ansermino JM. Augmented intelligence in pediatric anesthesia and pediatric critical care. Curr Opin Anesthesiol. 2020;33:404-10. https://doi.org/10.1097/ACO.0000000000000845
Joosten A, Jame V, Alexander B, Chazot T, Liu N, Cannesson M, et al. Feasibility of fully automated hypnosis, analgesia, and fluid management using 2 independent closed- loop systems during major vascular surgery: A Pilot Study. Anesthesia & Analgesia. 2018:5. https://doi.org/10.1213/ANE.0000000000003433
Zaouter C, Hemmerling TM, Lanchon R, Valoti E, Remy A, Leuillet S, et al. The feasibility of a completely automated total iv anesthesia drug delivery system for cardiac surgery. Anesthesia & Analgesia. 2016:9. https://doi.org/10.1213/ANE.0000000000001152
Zaouter C, Taddei R, Wehbe M, Arbeid E, Cyr S, Giunta F, et al. A novel system for automated propofol sedation: hybrid sedation system (HSS). Journal of Clinical Monitoring and Computing. 2017;31:309-17. https://doi.org/10.1007/s10877-016-9858-0
Kuck K, Johnson KB. The three laws of autonomous and closed-loop systems in anesthesia. Anesthesia & Analgesia. 2017;124(2):377-80. https:/doi.org/10.1213/ANE.0000000000001602
Ilyas M, Butt MFU, Bilal M, Mahmood K, Khaqan A, Riaz RA. A review of modern control strategies for clinical evaluation of propofol anesthesia administration employing hypnosis level regulation. BioMed Research International. 2017:12. https://doi.org/10.1155/2017/7432310
Puri GD, Mathew PJ, Biswas I, Dutta A, Sood J, Gombar S, et al. A multicenter evaluation of a closed-loop anesthesia delivery system: a randomized controlled trial. Anesthesia & Analgesia. 2016;122(1):106-14. https://doi.org/10.1213/ANE.0000000000000769
Mahajan V, Samra T, Puri GD. Anaesthetic depth control using closed loop anaesthesia delivery system vs. target controlled infusion in patients with moderate to severe left ventricular systolic dysfunction. Journal of Clinical Anesthesia. 2017:8. http://dx.doi.org/10.1016/j.jclinane.2017.07.014
Besch G, Vettoretti L, Claveau M, Boichut N, Mahr N, Bouhake Y, et al. Early post-operative cognitive dysfunction after closed-loop versus manual target controlled infusion of propofol and remifentanil in patients undergoing elective major non-cardiac surgery. Protocol of the randomized controlled single-blind POCD-ELA trial. Medicine. 2018;97(40):5. http://dx.doi.org/10.1097/MD.0000000000012558
Squara P, Chazot T, Auboin G, Fischler M, Dreyfus JF, Guen ML, et al. Behavior of a dual closed-loop controller of propofol and remifentanil guided by the bispectral index for postoperative sedation of adult cardiac surgery patients: a preliminary open study. Journal of Clinical Monitoring and Computing. 2020;34:779-86. https://doi.org/10.1007/s10877-019-00360-6
Neckebroek M, Boldingh J-WHL, Smet TD, Struys MMRF. Influence of remifentanil on the control performance of the bispectral index controlled bayesian-based closed-loop system for propofol administration. Anesthesia & Analgesia. 2020;130(6):1661-9. https://doi.org/10.1213/ANE.0000000000004208
Neckebroek M, Ionescu CM, Amsterdam Kv, Smet TD, Baets PD, Decruyenaere J, et al. A comparison of propofol-to-BIS post-operative intensive care sedation by means of target controlled infusion, Bayesian-based and predictive control methods: an observational, open-label pilot study. Journal of Clinical Monitoring and Computing. 2019;33:675-86. https://doi.org/10.1007/s10877-018-0208-2
Ma XD, Yan J, Dai BZ, Kong DQ, Du SY, Li BP. Comparative study: efficacy of closed-loop target controlled infusion of cisatracurium and other administration methods for spinal surgery of elderly patients. European Review for Medical and Pharmacological Sciences. 2017[acceso: 10/09/2020];21:606-11. Disponible en: https://www.europeanreview.org/wp/wp-content/uploads/606-611-Cisatracurium-via-CLTCI-in-the-elderly.pdf
Singaravelu S, Barclay P. Automated control of end-tidal inhalation anaesthetic concentration using the GE Aisys Carestation. British Journal of Anaesthesia. 2013;110:561-6. https://doi.org/10.1093/bja/aes464
Pasin L, Nardelli P, Pintaudi M, Greco M, Zambon M, Cabrini L, et al. Closed-loop delivery systems versus manually controlled administration of total iv anesthesia: A Meta-analysis of randomized clinical trials. Anesthesia & Analgesia. 2017;124(2):456-64. https://doi.org/10.1213/ANE.0000000000001394
Chan MTV, Hedrick TL, Egan TD, García PS, Koch S, Purdon PL, et al. American society for enhanced recovery and perioperative quality initiative joint consensus statement on the role of neuromonitoring in perioperative outcomes: electroencephalography. Anesthesia & Analgesia. 2020;130(5):1278-91. https://doi.org/10.1213/ANE.0000000000004502
Fahy BG, Chau DF. The technology of processed electroencephalogram monitoring devices for assessment of depth of anesthesia. Anesthesia & Analgesia. 2017:7. https://doi.org/10.1213/ANE.0000000000002331
Hammond JJ, Kirkendall WM, Calfee RV. Hypertensive crisis managed by computer controlled infusion of sodium nitroprusside: a model for the closed loop administration of short acting vasoactive agents. Comput Biomed Res. 1979;12(2):97-108. https://doi.org/10.1016/0010-4809(79)90008-9
Bednarski P, Siclari F, Voigt A, Demertzis S, Lau G. Use of a computerized closed-loop sodium nitroprusside titration system for antihypertensive treatment after open heart surgery. Critical Care Medicine. 1990;18(10):1061-5. https://doi.org/10.1097/00003246-199010000-00002
Kee WDN, Tam YH, Khaw KS, Ng FF, Lee SWY. Closed-loop feedback computer-controlled phenylephrine for maintenance of blood pressure during spinal anesthesia for cesarean delivery: a randomized trial comparing automated boluses versus infusion. Anesthesia & Analgesia. 2017;125(1):117-23. https://doi.org/10.1213/ANE.0000000000001974
Kee WDN, Khaw KS, Tam Y-H, Ng FF, Lee SW. Performance of a closed-loop feedback computer-controlled infusion system for maintaining blood pressure during spinal anaesthesia for caesarean section: a randomized controlled comparison of norepinephrine versus phenylephrine. Journal of Clinical Monitoring and Computing. 2016:7. https://doi.org/10.1007/s10877-016-9883-z
Joosten A, Alexander B, Duranteau J, Taccone FS, Creteur J, Vincent J-L, et al. Feasibility of closed-loop titration of norepinephrine infusion in patients undergoing moderate- and high-risk surgery. British Journal of Anaesthesia. 2019;123(4):430-8. https://doi.org/10.1016/j.bja.2019.04.064
Rinehart J, Ma M, Calderon MD, Cannesson M. Feasibility of automated titration of vasopressor infusions using a novel closed-loop controller. Journal of Clinical Monitoring and Computing. 2017:7. https://doi.org/10.1007/s10877-017-9981-6
Marques NR, Whitehead WE, Kallu UR, Kinsky MP, Funston JS, Wassar T, et al. Physician-directed versus computerized closed-loop control of blood pressure using phenylephrine in a swine model. Anesthesia & Analgesia. 2017;125(1):110-6. https://doi.org/10.1213/ANE.0000000000001961
Uemura K, Kawada T, Zheng C, Li M, Sugimachi M. Computer-controlled closed-loop drug infusion system for automated hemodynamic resuscitation in endotoxin induced shock. BMC Anesthesiology. 2017;17(145):13. https://doi.org/10.1186/s12871-017-0437-9
Marques NR, Ford BJ, Khan MN, Kinsky M, Deyo DJ, Mileski WJ, et al. Automated closed-loop resuscitation of multiple hemorrhages: a comparison between fuzzy logic and decision table controllers in a sheep model. Disaster and Military Medicine. 2017;3(1):10. https://doi.org/10.1186/s40696-016-0029-0
Joosten A, Delaporte A, Ickx B, Touihri K, Stany I, Barvais L, et al. Crystalloid versus colloid for intraoperative goal directed fluid therapy using a closed-loop system. A randomized, double-blinded, controlled trial in major abdominal surgery. Anesthesiology. 2017:12. https://doi.org/10.1097/ALN.0000000000001936
Gajdos M, Waitz M, Mendler MR, Braun W, Hummler H. Effects of a new device for automated closed loop control of inspired oxygen concentration on fluctuations of arterial and different regional organ tissue oxygen saturations in preterm infants. Arch Dis Child Fetal Neonatal. 2019[acceso: 11/09/2020];104:F360-5. http://dx.doi.org/10.1136/archdischild-2018-314769
Piquilloud L, Vignaux L, Bialais E, Roeseler J, Sottiaux T, Laterre PF. Neurally adjusted ventilatory assist improves patient-ventilator interaction. Intensiv Care Med. 2011;37:263-71. https://doi.org/10.1007/s00134-010-2052-9
Arnal JM, Garnero A, Novotni D, Corno G, Donati SY, Demory D. Closed loop ventilation mode in intensive care unit: a randomized controlled clinical trial comparing the numbers of manual ventilator setting changes. Minerva Anestesiologica. 2018;84:58-67. https://doi.org/10.23736/s0375-9393.17.11963-2
Thabit H, Hovorka R. Coming of age: the artificial pancreas for type 1 diabetes. Diabetología. 2016;59:1795-805. https://doi.org/10.1007/s00125-016-4022-4
Bergenstal RM, Garg S, Weinzimer SA. Safety of a hybrid closed-loop insulin delivery system in patients with type 1 diabetes. JAMA. 2016;316:1407-08. https://doi.org/10.1001/jama.2016.11708
Weisman A, Bai JW, Cardinez M, Kramer CK, Perkins BA. Effect of artificial pancreas systems on glycaemic control in patients with type 1 diabetes: a systematic review and meta-analysis of outpatient randomised controlled trials. Lancet Diabetes Endocrinol. 2017;5:501-12. https://doi.org/10.1016/S2213-8587(17)30167-5
Bekiari E, Kitsios K, Thabit H. Artificial pancreas treatment for outpatients with type 1 diabetes: systematic review and meta-analysis. BMJ. 2018;361:1310. https://doi.org/10.1136/bmj.k1310
Brogi E, Cyr S, Kazan R, Giunta F, Hemmerling TM. Clinical performance and safety of closed-loop systems: A systematic review and meta-analysis of randomized controlled trials. Anesthesia & Analgesia. 2017;124(2):446-55. https://doi.org/10.1213/ANE.0000000000001372