2020, Number 2
<< Back Next >>
CorSalud 2020; 12 (2)
Endocarditis due to corynebacterium after transcatheter aortic valve implantation: A case report
Hernández-Caballero A, Sotorrío-Simó V
Language: Spanish
References: 7
Page: 223-226
PDF size: 468.70 Kb.
ABSTRACT
We present a case of prosthetic valve endocarditis secondary to an infrequent organism (Corynebacterium sp.) after percutaneous aortic valve implantation. The lower sensitivity of transesophageal echocardiogram to detect signs of endocarditis in these patients may delay diagnosis. Implementing other ancillary imaging techniques such as positron emission tomography may be helpful. The increase in percutaneous prosthetic implants in recent years is associated with an upsurge in complications such as endocarditis.
REFERENCES
Cribier A, Eltchaninoff H, Bash A, Borenstein N, Tron C, Bauer F, et al. Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description. Circulation. 2002;106(24):3006-8.
Loh PH, Bundgaard H, S Ndergaard L. Infective endocarditis following transcatheter aortic valve replacement: diagnostic and management challenges. Catheter Cardiovasc Interv. 2013;81(4):623-7.
Amat-Santos IJ, Messika-Zeitoun D, Eltchaninoff H, Kapadia S, Lerakis S, Cheema AN, et al. Infective endocarditis after transcatheter aortic valve implantation: results from a large multicenter registry. Circulation. 2015;131(18):1566-74.
Aranzulla TC, De Benedictis M, Asteggiano R. Follow-up management after transcatheter aortic valve implantation (TAVI). E-J Cardiol Pract [Internet). 2016 [citado 26/05/2019];14(7). Disponible en: https://www.escardio.org/Journals/E-Journal-of-Cardiology-Practice/Volume-14/Follow-up-management-after-transcatheter-aortic-valve-implantation-TAVI
Pedersen WR, Walker M, Olson JD, Gobel F, Lange HW, Daniel JA, et al. Value of transesophageal echocardiography as an adjunct to transthoracic echocardiography in evaluation of native and prosthetic valve endocarditis. Chest. 1991;100(2):351-6.
Lengyel M. The impact of transesophageal echocardiography on the management of prosthetic valve endocarditis: experience of 31 cases and review of the literature. J Heart Valve Dis. 1997;6(2):204-11.
Puls M, Eiffert H, Hünlich M, Schöndube F, Hasenfuß G, Seipelt R, et al. Prosthetic valve endocarditis after transcatheter aortic valve implantation: the incidence in a single-centre cohort and reflections on clinical, echocardiographic and prognostic features. EuroIntervention. 2013;8(12):1407-18.