ABSTRACT
Introduction: the reverse transcriptase polymerase chain reaction is a highly precise technique in the detection and amplification of genetic material, and therefore in the detection of viruses.Objective: to describe the bases of the use of the polymerase chain reaction with reverse transcriptase as a diagnostic test in the detection of SARS-CoV-2.
Method: a literature review was carried out on articles published up to May 2020. The following databases were consulted: Scopus, Wiley Online Library, SciELO, DIALNET, EBSCO, MEDLINE and PubMed. Articles in Spanish and English were retrieved, selecting 43 references.
Development: The reverse transcriptase polymerase chain reaction to detect SARS-CoV-2 consists of reading RNA-dependent RNA polymerase, ORF1ab fragments, the E gene, the N gene, and the S gene. The nasopharyngeal exudate offers better results than oropharyngeal and saliva as sample. The inclusion of reverse transcriptase polymerase chain reaction tests using rectal swab specimens is necessary in suspected false negative cases. New studies and techniques are developed with the aim of optimizing the detection process.
Conclusions: the availability of diagnostic tests is crucial for the isolation of positive cases and the monitoring of the epidemiological chain of transmission. RT-PCR turned out to be the test of choice during the viral replication period. The RT-LAMP assay is a rapid diagnostic alternative with similar principles to RT-PCR.
REFERENCES
Arshad-Ali S, Baloch M, Ahmed N, Arshad-Ali A, Iqbal A. The outbreak of Coronavirus Disease 2019 (COVID-19) - An emerging global health threat. Journal of Infection and Public Health [Internet]. 2020 [citado 15 mayo 2020]; 13(2020): 644-646. Disponible en: https://www.sciencedirect.com/science/article/pii/S1876034120303658
Shao-Chung C, Yuan-Chia C, Yu-Long FC, Yu-Chan C, Mingte C, Yang CH et al. First case of Coronavirus Disease 2019 (COVID-19) pneumonia in Taiwan. Journal of the Formosan Medical Association [Internet]. 2020 [citado 27 abril 2020]; 119(3): 747-751. Disponible en: https://www.sciencedirect.com/science/article/pii/S0929664620300449
Wu A, Peng Y, Huang B, Ding X, Wang X, Niu P et al. Genome Composition and Divergence of the Novel Coronavirus (2019-nCoV) Originating in China. Cell Host & Microbe [Internet]. 2020. [citado 2 mayo 2020]; 27(3): 325-328. Disponible en: https://www.sciencedirect.com/science/article/pii/S193131282030072X
Lorussoa A, Calistria P, Mercantea MT, Monacoa F, Portanti O, Marcacci M et al. A “One-Health” approach for diagnosis and molecular characterization of SARS-CoV-2 in Italy. One Health [Internet]. 2020 [citado 5 mayo 2020]; 10 (2020): 100135. Disponible en: https://www.sciencedirect.com/science/article/pii/S2352771420300823
Ding-feng L, Qi-ming Ying, Yue-song Weng, Chi-bin Shen, Jin-guo Chu, Kong J et al. Dynamic change process of target genes by RT-PCR testing of SARS-Cov-2 during the course of a Coronavirus Disease 2019 patient. Clinica Chimica Acta [Internet]. 2020 [citado 5 mayo 2020]; 506(Julio 2020): 172-175. Disponible en: https://www.sciencedirect.com/science/article/pii/S0009898120301340
Tang-Xiao A, Xin-Tong Y, Gao C, Zhu L, Jie-Zhang Y, Zhang S. Dynamic profile of RT-PCR findings from 301 COVID-19 patients in Wuhan, China: A descriptive study. Journal of Clinical Virology [Internet]. 2020 [citado 12 mayo 2020]; 127(Junio 2020): 104346. Disponible en: https://doi.org/10.1016/j.jcv.2020.104346
Hogan C, Sahoo M, Hong-Huang C, Garamani N, Stevens B. Comparison of the Panther Fusion and a laboratory-developed test targeting the envelope gene for detection of SARS-CoV-2. Journal of Clinical Virology [Internet]. 2020 [citado 12 mayo 2020]; 127 (Junio 2020): 104383. Disponible en: https://doi.org/10.1016/j.jcv.2020.104383
Ishigea T, Murataa S, Taniguchib T, Miyabea A, Kitamuraa K, Kawasaki K et al. Highly sensitive detection of SARS-CoV-2 RNA by multiplex rRT-PCR for molecular diagnosis of COVID-19 by clinical laboratories. Clinica Chimica Acta [Internet]. 2020 [citado 5 mayo 2020]; 507(agosto 2020): 139-142. Disponible en: https://www.sciencedirect.com/science/article/pii/S0009898120301789
Fuk-Woo-Chan J, Chik-Yan-Yip C, Kai-Wang-To K, Hing-Cheung-Tang T, Cheuk-Ying-Wong S, Leung KH et al. Improved Molecular Diagnosis of COVID-19 by the Novel, Highly Sensitive and Specific COVID-19-RdRp/Hel Real-Time Reverse Transcription-PCR Assay Validated In Vitro and with Clinical Specimens. Journal of Clinical Microbiology [Internet]. 2020 [citado 18 mayo 2020]; 58:e00310-20. Disponible en: https://jcm.asm.org/content/58/5/e00310-20.long
Wolters F, Van de Bovenkamp J, Van den Bosch B, Van den Brink S, Broeders M, Chung-Hoa N et al. Multi-center evaluation of cepheid xpert® xpress SARS-CoV-2 point-of-care test during the SARS-CoV-2 pandemic. Journal of Clinical Virology [Internet] 2020 [citado 14 mayo 2020];128(Julio 2020): 104426. Disponible en: https://dx.doi.org/10.1016/j.jcv.2020.104426
Liu R, Han H, Liu F, Lv Z, Wu K, Liu Y et al. Positive rate of RT-PCR detection of SARS-CoV-2 infection in 4880 cases from one hospital in Wuhan, China, from Jan to Feb 2020. Clin Chim Acta [Internet]. 2020 [citado 8 mayo 2020]; 505(Junio 2020): 172–175. Disponible en: https://doi.org/10.1016/j.cca.2020.03.009
Wang X, Tan L, Wang X, Liu W, Lu Y, Cheng L et al. Comparison of nasopharyngeal and oropharyngeal swabs for SARS-CoV-2 detection in 353 patients received tests with both specimens simultaneously. International Journal of Infectious Diseases [Internet]. 2020 [citado 5 mayo 2020]; 94(Mayo2020): 107-109. Disponible en: https://www.sciencedirect.com/science/article/pii/S1201971220302356
Wang X, Zhou Y, Jiang N, Zhou Q, Ma W-L. Persistence of intestinal SARS-CoV-2 infection in patients with COVID-19 leads to re-admission after pneumonia resolved. International Journal of Infectious Diseases (2020) [Internet]. 2020 [citado 12 mayo 2020]; 95(2020): 433-435. Disponible en: https://doi.org/10.1016/j.ijid.2020.04.063
Hoffmann M, Kleine-Weber H, Schroeder S, Krüger N, Herrler T, Erichsen S et al. SARS-CoV-2 Cell Entry Depends on ACE2 and TMPRSS2 and Is Blocked by a Clinically Proven Protease Inhibitor. Cell [Internet]. 2020 [citado 5 mayo 2020]; 181:(2) 271-280.e8 . Disponible en: https://www.sciencedirect.com/science/article/pii/S0092867420302294
Williams E, Bond K, Zhang B, Putland M, Williamson D. Saliva as a non-invasive specimen for detection of SARS-CoV-2. Journal of Clinical Microbiology [Internet]. 2020 [citado 5 mayo 2020]; [In Press]:JCM.00776-20 . Disponible en: https://jcm.asm.org/content/jcm/early/2020/04/17/JCM.00776-20.full.pdf
Nörz D, Fischer N, Schultze A, Kluge S, Mayer-Runge U. Clinical evaluation of a SARS-CoV-2 RT-PCR assay on a fully automated system for rapid on-demand testing in the hospital setting. Journal of Clinical Virology [Internet]. 2020 [citado 12 mayo 2020]; 128 (Junio 2020): 104390. Disponible en: https://doi.org/10.1016/j.jcv.2020.104390
Poljak M, Korva M, Knap-Gašper N, Fujs-Komloš K, Sagadin M. Clinical evaluation of the cobas SARS-CoV-2 test and a diagnostic platform 2 switch during 48 hours in the midst of the COVID-19 pandemic. Journal of Clinical Microbiology [Internet]. 2020 [citado 12 mayo 2020] 58:e00599-20. Disponible en: http://doi.org/10.1128/JCM.00599-20
Yan C, Cui J, Huang L, Du B, Chen L, Xue G et al. Rapid and visual detection of 2019 novel coronavirus (SARS-CoV-2) by a reverse transcription loop-mediated isothermal amplification assay. Clinical Microbiology and Infection [Internet]. 2020 [citado 5 mayo 2020];26(6): 773-779. Disponible en: https://www.sciencedirect.com/science/article/pii/S1198743X20301865
Gun-Soo, Keunbon P, Seung-Hwa K, Seong-Jun B, Seung K, Kim BT et al. Development of Reverse Transcription Loop-Mediated Isothermal Amplification Assays Targeting Severe Acute Respiratory Syndrome Coronavirus 2. The Journal of Molecular Diagnostics [nternet]. 2020 [citado 5 mayo 2020];22(6): 729-735. Disponible en: https://www.sciencedirect.com/science/article/pii/S1525157820300908
Lin Y, Wu S, Hao X, Li X, Liu X, Ye S et al. Rapid Detection of COVID-19 Coronavirus Using a Reverse Transcriptional Loop-Mediated Isothermal Amplification (RT-LAMP) Diagnostic Platform. Clinical Chemistry [Internet]. 2020 [citado 13 julio 2020]; 66(7): 975-977. Disponible en: https://academic.oup.com/clinchem/article/66/7/975/5823294