2020, Number 4
<< Back Next >>
Rev Cub Oftal 2020; 33 (4)
Qualitative evaluation of filtering blebs
Pérez RY, Fumero GFY, Chaviano LG, Álvarez CGA, Rangel HME
Language: Spanish
References: 19
Page: 1-13
PDF size: 634.85 Kb.
ABSTRACT
A review was conducted on the qualitative evaluation of the filtering bleb. The conjunctival bleb is the visible part of filtration surgery, and its morphology is an indicator of factors which may determine the hypotensive result of surgery and the possible postoperative complications. Various studies have been conducted which relate the clinical evaluation of its morphology and intraocular pressure control. Several grading systems have thus been established: Wuerzburg Bleb Classification Score, Moorfields Bleb Grading System, Indiana Bleb Appearance Grading Scale and imaging methods to evaluate the anterior segment (ultrasound biomicroscopy, Heidenberg retinal tomography and optical coherence tomography). These methods are a useful tool for the follow-up of filtration surgery and its documentation.
REFERENCES
Razeghinejad MR, Fudemberg SJ, Spaeth GL. The changing conceptual basis oftrabeculectomy: a review of past and current surgical techniques. Surv Ophthalmol. 2012;57(1):1-25.
Koike KJ, Chang PT. Trabeculectomy: A Brief History and Review of Current Trends. Int Ophthalmol Clin. 2018;58(3):117-33.
Sobeih DH, Cotran PR. Posterior Surgical Revision of Failed Fornix-basedTrabeculectomy: J Glauc. 2017;26(10):947-53.
Klink T, Kann G, Ellinger P, Klink J, Grehn F, Guthoff R. The Prognostic Value of theWuerzburg Bleb Classification Score for the Outcome of Trabeculectomy. Ophthalmologica. 2011;225(1):55-60.
Furrer S, Menke MN, Funk J, Töteberg-Harms M. Evaluation of filtering blebs usingthe Wuerzburg bleb classification score compared to clinical findings. BMC Ophthalmol. 2012 [acceso: 25/03/2019];12(1). Disponible en http://bmcophthalmol. biomedcentral. com/articles/10. 1186/1471-241512-24
Klink T, Schrey S, Elsesser U, Klink J, Schlunck G, Grehn F. Interobserver Variabilityof the W & UUML; Rzburg Bleb Classification Score. Ophthalmologica. 2008;222(6):40813.
Wells AP, Ashraff NN, Hall RC, Purdie G. Comparison of two clinical Bleb gradingsystems. Ophthalmology. 2006;113(1):77-83.
Sousa DC, Pinto LA. Trabeculectomy – Prevention and Management ofComplications. Eur Ophth Rev. 2018;12(2):98.
Wells AP, James K, Birchall W, Wong T. Information Loss in 2 Bleb Grading Systems:J Glaucoma. 2007;16(2):246-50.
Cantor LB, Mantravadi A, WuDunn D, Swamynathan K, Cortes A. MorphologicClassification of Filtering Blebs after Glaucoma Filtration Surgery: The Indiana Bleb Appearance Grading Scale: J Glauc. 2003;12(3):266-71.
Wells AP, Crowston JG, Marks J, et al. A Pilot Study of a System for Grading ofDrainage Blebs after Glaucoma Surgery. J Glauc. 2004;13(6):454-60.
Khaw P, Dhingra S. The Moorfields safer surgery system. Middle East Afr JOphthalmol. 2009;16(3):112.
Klink T, Guthoff R, Grehn F, Schlunck G. Nachsorgenach filtrieren den Glaukomoperation. Ophthalmology. 2006;103(9):815-26.
Hamanaka T, Omata T, Sekimoto S, Sugiyama T, Fujikoshi Y. Bleb Analysis byUsing Anterior Segment Optical Coherence Tomography in Two Different Methods of Trabeculectomy. Invest Opthalmol Vis Sci. 2013;54(10):6536.
El Salhy AA, Elseht RM, Al Maria AF, Shalaby SMAE, Hossein TR. Functionalevaluation of the filtering bleb by ultrasound biomicroscopy after trabeculectomy with mitomycin C. Int J Ophthalmol. 2018;11(2):245-50.
Yamamoto T, Sakuma T, Kitazawa Y. Αn ultrasound biomicroscopic study offiltering blebs after mitomycin C trabeculectomy. Ophthalmology. 1995;102(12):1770-6.
Hirooka K, Takagish M. Status Optical Coherence Tomography study of filteringblebs after prymary trabeculectomy with a fornix- bas conjuntival flap. Acta Ophthalmol. 2010;88:60-4.
Kokubun T, Kunikata H, Tsuda S, Himori N, Maruyama K, Nakazawa T. Quantification of the filtering bleb's structure with anterior segment optical coherence tomography. Clin Experim Ophthalmol. 2016;44(6):446-54.
Cerdá-Ibáñez M. Análisis cualitativo de ampollas de filtración reparadas mediantetomografía de coherencia óptica del segmento anterior. Arch Soc Esp Oftalmol. 2017. DOI: http://dx. doi. org/10. 1016/j. oftal. 2016. 11. 015