2020, Number 3
<< Back Next >>
Rev Cub Oftal 2020; 33 (3)
Results of intraocular lens calculation with the Holladay 2 formula in cataract patients
Veitía RZA, Hernández GME, Pérez CEC, Rodríguez SB, Méndez DAM, Hernández LI
Language: Spanish
References: 25
Page: 1-15
PDF size: 627.09 Kb.
ABSTRACT
Objective:
Determine refractive results in patients undergoing cataract surgery based on intraocular lens dioptric power calculation with the Holladay 2 formula.
Methods:
A prospective longitudinal descriptive study was conducted of 222 eyes of 173 patients undergoing cataract surgery by phacoemulsification technique. IOL Master 700 and the Holladay 2 formula were used for lens calculation.
Results:
There was a predominance of the female sex and the over-60 years age group. The postoperative period was characterized by improvement in visual acuity without correction and corrected of more than 4 lines on the Snellen chart, regardless of axial length, with no significant changes in the keratometric cylinder. In 69.0% of the cases, the final refractive result was within the range of emmetropia. Eyes larger than 26 mm displayed a spherical equivalent reduction above 6 diopters postoperative, whereas eyes smaller than 22 mm showed the greatest difference between the dioptric power of the intraocular lens implanted and the one suggested by the conventional formula.
Conclusion:
The Holladay 2 formula is useful for intraocular lens calculation in all axial length ranges.
REFERENCES
Hernández Iramis M, Hernández Silva JR, Río Torres M, Ruiz Rodríguez Y, Del Amo Freire J, Vargas Acelia B. Evaluación del equipo de interferometría óptica de coherencia parcial Lenstar en la biometría ocular. Rev Cubana Oftalmol. 2010 [acceso: 21/04/2017];3(2):[aprox. 9 p.]. Disponible en: http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S0864-21762010000400001
Pacheco Sanz M. Biometría y cálculo de lentes intraoculares [Tesis]. Zaragoza: Universidad Zaragoza; 2014.
Hernández Silva JR, Pérez Llanes A, Galá Herrera LE, Ramos López M, Veitía Robirosa Z, Padilla González C. Resultados del cálculo del poder del lente intraocular mediante la fórmula de Haigis. Rev Cubana Oftalmol [Internet]. 2010 [acceso: 21/04/2017];23(3):[aprox. 14 p.]. Disponible en: http://www.bvs.sld.cu/revistas/oft/vol23_3_10/oft08310.htm
Gómez Lara FJ. Comparación de fórmulas biométricas en el cálculo de lentes intraoculares mediante el uso de biometría óptica [Tesis]. Cataluña: Universidad Politécnico de Cataluña: Facultad de Óptica y Optometría de Terrassa; 2013.
Torres Hernández L. Estudio de técnicas biométricas y cálculo de la lente intraocular [Tesis]. Valladolid: Universidad de Valladolid; 2012.
De Juan Herráez MV. Estudio clínico comparativo de la refracción obtenida tras facoemulsificación con implante de lente intraocular al realizar la biometría con el IOL Master y el OTISCAN-1000 en función de la longitud axial [Tesis]. Valladolid: Universidad de Valladolid: Instituto Universitario de Oftalmobiología Aplicada (IOBA); 2012.
Millbank L. Accurate optical biometry using the IOL Master Carl Zeiss Meditec. Internat J Ophth Pract [Internet]. 2011 [acceso: 21/04/2017];2(1):[aprox. 9 p.]. Disponible en: http://218.248.31.202/librarymain/files/mlopresources/Optical_Biometry.pdf
Río Torres M. Historia del Instituto Cubano de Oftalmología "Ramón Pando Ferrer". Rev Cubana Oftalmol [Internet]. 2016 [acceso: 21/04/2017]29(2):[aprox. 7 p.]. Disponible en: http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S0864-21762016000200017
Stattin M, Zehetner C, Bechrakis NE, Speicher L. Comparison of IOL-Master 500 vs. Lenstar LS900 concerning the calculation of target refraction: A retrospective analysis. Ophthalmologe. 2015;112(5):444-50.
Du YL, Wang G, Huang HC, Lin LY, Jin C, Liu LF, et al. Comparison of OA-2000 and IOL Master 500 using in cataract patients with high myopia. Int J Ophthalmol. 2019;12(5):844-7.
Mengchan S. Biometric measurements in the crystalline lens: applications in cataract surgery [Tesis doctoral]. Universidad de Valladolid. Facultad de Medicina; 2017.
Ministerio de Salud Pública. Anuario estadístico de Salud. La Habana: Dirección de Registros médicos de Cuba; 2019.
David L, Cooke DL, Cooke TL. Comparison of 9 intraocular lens power calculation. J Cataract Refract Surg. 2016;42:1157-64.
Melles RB, Holladay JT, Chang WJ. Accuracy of Intraocular Lens Calculation Formulas. Ophthalmology. 2018;125:169-78.
Corelette C, Arndt C, Vidal J, Afriat M, Durbant E, Brugniart C, Ducasse A, favre F, Denoyer A. Is Holladay 2 formula acurate enough for calculating intraocular lens power in non-standard eye? J Fr Ophthalmol. 2018;41(4):308-14.
Reitblat O, Assia Ei, Kleinmann G, Levy A, Barrett GD, Abulafia A. Accuracy of predicted refraction with multifocal intraocular lens power calculation formulas. Clin Exp Ophthalmol. 2015;43(4).2.
Shrivastava AK, Behera P, Kumar B, Nada S. Precision of intraocular lens power prediction in eyes shorter than 22 mm: An analysis of 6 formulas. J Cataract Refract Surg. 2018;44(11):1317-20.
Eye World. IOL calculations: U.S. and international surgeons differ on formula preference. EyeWorld news magazine; 2015 [acceso: 21/04/2017]. Disponible en: https://www.eyeworld.org/article-iol-calculations--u-s--and-international-surgeons-differ-on-formula-preference
Olsen T, Hoffmann P. C constant: new concept for ray tracingassisted intraocular lens power calculation. J Cataract Refract Surg. 2015;40:764-73.
Kane JX, Van Heerden A, Atik A, Petsoglou C. Intraocular lens power formula accuracy: comparison of 7 formulas. J Cataract Refract Surg. 2016;42:1490-500.
Hoffer KJ, Aramberri J, Haigis W, et al. Protocols for studies of intraocular lens formula accuracy [editorial]. Am J Ophthalmol. 2015;160:403-5.
Findl O, Haigis W, Hoffer KJ. IOL Master 700: Cutting-edge IOL power calculation. Barcelona: Communication presented at ESCRS Congress; 2015.
Aramberri J. IOL Master 700: Clinical experience. Barcelona: Communication presented at the ESCRS Congress; 2015.
Cooke DL, Cooke TL. Prediction accuracy of preinstalled formulas on two optical biometers. J Cataract Refract Surg. 2016;42:358-62.
Ladas JG, Siddiqui AA, Devgan U, Jun AS. A 3-D "super surface" combining modern intraocular lens formulas to generate a "super formula" and maximize accuracy. JAMA Ophthalmol. 2015;133:1431-6.