2016, Número 5
<< Anterior Siguiente >>
Rev Invest Clin 2016; 68 (5)
Therapeutic Effects of Bipolar Coagulation Forceps on Open Thyroid Surgery
Su L, Li J, Tang X, Sang J
Idioma: Ingles.
Referencias bibliográficas: 20
Paginas: 256-261
Archivo PDF: 98.46 Kb.
RESUMEN
Sin resumen.
REFERENCIAS (EN ESTE ARTÍCULO)
Pandav CS, Yadav K, Srivastava R, Pandav R, Karmarkar MG. Iodine deficiency disorders (IDD) control in India. Indian J Med Res. 2013;138:418-33.
Di BG, Fabozzi A, Rinaldi C. Clinical management of thyroid nodules with indeterminate cytology: our institutional experience using SIAPEC cytological criteria and V600-BRAF test. Pathologica. 2013;105:1-4.
Kocher T. [On goiter removal, and its consequences]. Arch Klin Chir. 1883;29:254-337.
Dhepnorrarat RC, Witterick IJ. New technologies in thyroid cancer surgery. Oral Oncol. 2013;49:659-64.
G rant CS. Recurrence of papillary thyroid cancer after optimized surgery. Gland Surg. 2015;4:52-62.
Yen WY, Qiu W. The feasibility of total or near-total bilateral thyroidectomy for the treatment of bilateral multinodular goiter. J Invest Surg. 2009;22:195-200.
A lhan E, Usta A, Türkyılmaz S. Total thyroidectomy for management of benign multinodular goitre in an endemic region: review of 620 cases. Acta Chir Belg. 2005;115:198-201.
L orente-Poch L, Sancho JJ, Ruiz S, Sitges-Serra A. Importance of in situ preservation of parathyroid glands during total thyroidectomy. Br J Surg. 2015;102:359-67.
Yen WY, Qiu W. The feasibility of total or near-total bilateral thyroidectomy for the treatment of bilateral multinodular goiter. J Invest Surg. 2009;22:195-200.
Hwang SO, Jung JH, Park HY, Kim WW. A prospective, randomized study between the small jaw® and the Harmonic Focus® in open thyroidectomy. Otolaryngol Head Neck Surg. 2014; 150:943-8.
T eksoz S, Bukey Y, Ozcan M, Arikan AE, Ozyegin A. Sutureless thyroidectomy with energy-based devices: Cerrahpasa experience. Updates Surg. 2013;65:301-7.
Konturek A, Barczynski M, Stopa M, Nowak W. Total thyroidectomy for non-toxic multinodular goiter with versus without the use of harmonic FOCUS dissecting shears-a prospective randomized study. Wideochir Inne Tech Maloinwazyjne. 2012;7: 268-74.
Yildirim O, Umit T, Ebru M, et al. Ultrasonic harmonic scalpel in total thyroidectomies. Adv Ther. 2008;25:260-5.
Kwak HY, Chae BJ, Park YG, et al. Comparison of surgical outcomes between papillary thyroid cancer patients treated with the Harmonic ACE scalpel and LigaSure Precise instrument during conventional thyroidectomy: a single-blind prospective randomized control trial. J Surg Res. 2014;187:484-9.
Zanghì A, Cavallaro A, Di Vita M, et al. The safety of the Harmonic ® Focus in open thyroidectomy: a prospective, randomized study comparing the Harmonic® Focus and traditional suture ligation (knot and tie) technique. Int J Surg. 2014;12(Suppl 1): S132-5.
Ciftci F, Sakalli E, Abdurrahman I, Guler B. Parathyroid function following total thyroidectomy using energy devices. Eur Arch Otorhinolaryngol. 2016;273:1905-11.
E lliott-Lewis EW, Mason AM, Barrow DL. Evaluation of a new bipolar coagulation forceps in a thermal damage assessment. Neurosurgery. 2009;65:1182-7.
G uo JY, Li DW, Liao R, et al. Outcomes of simple saline-coupled bipolar electrocautery for hepatic resection. World J Gastroenterol. 2014;20:8638-45.
Hefermehl LJ, Largo RA, Hermanns T, Poyet C, Sulser T, Eberli D. Lateral temperature spread of monopolar, bipolar and ultrasonic instruments for robot-assisted laparoscopic surgery. BJU Int. 2014;114:245-52.
Walen SG, Rudmik LR, Dixon E, Matthews TW, Nakoneshny SC, Dort JC. The utility of the harmonic scalpel in selective neck dissection: a prospective, randomized trial. Otolaryngol Head Neck Surg. 2011;144:894-9.