2013, Número 4
<< Anterior Siguiente >>
Ann Hepatol 2013; 12 (4)
Non-invasive assessment of liver fibrosis with transient elastography (FibroScan®): applying the cut-offs of M probe to XL probe
Lai-Hung WG, Vergniol J, Lo P, Wai-Sun WV, Foucher J, Le Bail B, Cheung-Lung CP, Chermak F, Kwong-Sak L, Merrouche W, Lik-Yuen CH, de Lédinghen V
Idioma: Ingles.
Referencias bibliográficas: 25
Paginas: 402-412
Archivo PDF: 166.99 Kb.
RESUMEN
Sin resumen.
REFERENCIAS (EN ESTE ARTÍCULO)
Wong VW, Chan HL. Transient elastography. J Gastroenterol Hepatol 2010; 25: 1726-31. Doi: 10.1111/j.1440- 1746.2010.06437.x.
Tsochatzis EA, Gurusamy KS, Ntaoula S, Cholongitas E, Davidson BR, Burroughs AK. Elastography for the diagnosis of severity of fibrosis in chronic liver disease: a meta-analysis of diagnostic accuracy. J Hepatol 2011; 54: 650-9. Doi: 10.1016/j.jhep.2010.07.033.
Castéra L, Vergniol J, Foucher J, Le Bail B, Chanteloup E, Haaser M, Darriet M, et al. Prospective comparison of transient elastography, Fibrotest, APRI, and liver biopsy for the assessment of fibrosis in chronic hepatitis C. Gastroenterology 2005; 128: 343-50.
Chan HL, Wong GL, Choi PC, Chan AW, Chim AM, Yiu KK, Chan FK, et al. Alanine aminotransferase-based algorithms of liver stiffness measurement by transient elastography (Fibroscan) for liver fibrosis in chronic hepatitis B. J Viral Hepat 2009; 16:36-44. Doi: 10.1111/j.1365- 2893.2008.01037.x.
Wong VW, Vergniol J, Wong GL, Foucher J, Chan HL, Le Bail B, Choi PC, et al. Diagnosis of fibrosis and cirrhosis using liver stiffness measurement in nonalcoholic fatty liver disease. Hepatology 2010; 51: 454-62. Doi: 10.1002/ hep.23312.
Castéra L, Foucher J, Bernard PH, Carvalho F, Allaix D, Merrouche W, Couzigou P, et al. Pitfalls of liver stiffness measurement: a 5-year prospective study of 13,369 examinations. Hepatology 2010; 51: 828-35. Doi: 10.1002/ hep.23425.
Wong GL, Wong VW, Chim AM, Yiu KK, Chu SH, Li MK, Chan HL. Factors associated with unreliable liver stiffness measurement and its failure with transient elastography in the Chinese population. J Gastroenterol Hepatol 2011; 26: 300-5. Doi: 10.1111/j.1440-1746.2010.06510.x.
Finucane MM, Stevens GA, Cowan MJ, Danaei G, Lin JK, Paciorek CJ, Singh GM, et al. National, regional, and global trends in body-mass index since 1980: systematic analysis of health examination surveys and epidemiological studies with 960 country-years and 9.1 million participants. Lancet 2011; 377: 557-67. Doi: 10.1016/S0140- 6736(10)62037-5.
de Ledinghen V, Vergniol J, Foucher J, El-Hajbi F, Merrouche W, Rigalleau V. Feasibility of liver transient elastography with FibroScan using a new probe for obese patients. Liver Int 2010; 30: 1043-8. Doi: 10.1111/j.1478- 3231.2010.02258.x.
de Lédinghen V, Wong VW, Vergniol J, Wong GL, Foucher J, Chu SH, Le Bail B, et al. Diagnosis of liver fibrosis and cirrhosis using liver stiffness measurement: comparison between M and XL probe of FibroScan(R). J Hepatol 2012; 56: 833-9. Doi: 10.1016/j.jhep.2011.10.017.
Friedrich-Rust M, Hadji-Hosseini H, Kriener S, Herrmann E, Sircar I, Kau A, Zeuzem S, et al. Transient elastography with a new probe for obese patients for non-invasive staging of non-alcoholic steatohepatitis. Eur Radiol 2010; 20: 2390-6. Doi: 10.1007/s00330-010-1820-9.
Myers RP, Pomier-Layrargues G, Kirsch R, Pollett A, Duarte- Rojo A, Wong D, Beaton M, et al. Feasibility and diagnostic performance of the FibroScan XL probe for liver stiffness measurement in overweight and obese patients. Hepatology 2012; 55: 199-208. Doi: 10.1002/hep.24624.
Wong VW, Vergniol J, Wong GL, Foucher J, Chan AW, Chermak F, Choi PC, et al. Liver Stiffness Measurement Using XL Probe in Patients With Nonalcoholic Fatty Liver Disease. Am J Gastroenterol 2012. Doi: 10.1038/ ajg.2012.331.
Chan HL, de Silva HJ, Leung NW, Lim SG, Farrell GC, Asia- Pacific Working Party on N. How should we manage patients with non-alcoholic fatty liver disease in 2007? J Gastroenterol Hepatol 2007; 22: 801-8. Doi: 10.1111/ j.1440-1746.2007.04977.x.
Kaplan MM, Gershwin ME. Primary biliary cirrhosis. N Engl J Med 2005; 353: 1261-73. Doi: 10.1056/NEJMra043898.
Krawitt EL. Autoimmune hepatitis. N Engl J Med 2006; 354: 54-66. Doi: 10.1056/NEJMra050408.
Wong GL, Wong VW, Choi PC, et al. Metabolic syndrome increases the risk of liver cirrhosis in chronic hepatitis B. Gut 2009; 58: 111-7. Doi: 10.1136/gut.2008.157735.
Bedossa P, Poynard T. An algorithm for the grading of activity in chronic hepatitis C. The METAVIR Cooperative Study Group. Hepatology 1996; 24: 289-93. Doi: 10.1002/ hep.510240201.
Brunt EM, Janney CG, Di Bisceglie AM, Neuschwander-Tetri BA, Bacon BR. Nonalcoholic steatohepatitis: a proposal for grading and staging the histological lesions. Am J Gastroenterol 1999; 94: 2467-74. Doi: 10.1111/j.1572- 0241.1999.01377.x.
Breiman L, Friedman J, Stone CJ, Olshen RA. Classification and Regression Trees. Chapman and Hall/CRC1 ed. 1984.
McLachlan GJ, Do AN, Ambroise C. Analyzing microarray gene expression data. Wiley 2004.
Stehman SV. Selecting and interpreting measures of thematic classification accuracy. Remote Sensing of Environment 1997; 62: 77-89.
Wong GL, Chan HL, Choi PC, Chan AW, Lo AO, Chim AM, Wong VW. Association between Anthropometric Parameters and Measurements of Liver Stiffness by Transient Elastography. Clin Gastroenterol Hepatol 2012. Doi: 10.1016/j.cgh.2012.09.025.
Wong VW, Chu WC, Wong GL, Chan RS, Chim AM, Ong A, Yeung DK, et al. Prevalence of non-alcoholic fatty liver disease and advanced fibrosis in Hong Kong Chinese: a population study using proton-magnetic resonance spectroscopy and transient elastography. Gut 2012; 61: 409-15. Doi: 10.1136/gutjnl-2011-300342.
Das K, Sarkar R, Ahmed SM, Mridha AR, Mukherjee PS, Das K, Dhali GK, et al. Normal liver stiffness measure (LSM) values are higher in both lean and obese individuals: a population- based study from a developing country. Hepatology 2012; 55: 584-93. Doi: 10.1002/hep.24694.