Embolia accidental de stent coronario a sistema arterial periférico
Palomo VJA, Ledesma VM, Skromne KD
Idioma: Español
Referencias bibliográficas: 19
Paginas: 30-36
Archivo PDF: 267.82 Kb.
RESUMEN
Potential complications of intracoronary stenting include stent dislodgment and embolization. We describe a three patients in whom a stent was migrated from the coronary artery to the iliac artery. Una de las posibles complicaciones relacionadas con la implantación del stent intracoronario es la embolización del mismo. En este informe describimos tres casos de migración accidental de la férula endovascular a territorio arterial periférico. El desprendimiento se debió a una técnica deficiente al intentar su colocación en el sitio programado.
REFERENCIAS (EN ESTE ARTÍCULO)
Roubin G, Cannon A, Agrawal S, Dean L, Baxley W, Breland J. Intracoronary stening for acute and threatened clouse complicating percutaneous transluminal coronary angioplasty. Circulation 1992; 851: 916-927.
Schatz R, Baim D, Leon M, Ellis S, Golberg S et al. Clinical experience with the Palmaz-Schatz coronary stent; initial results of a multicenter study. Circulation 1991; 83: 148-161.
Ledesma M, Farell J, Astudillo R, Abundes A, Escudero X, Montoya S et al. Stents: Experiencia en el Hospital de Cardiología del Centro Médico Nacional Siglo XXI. Arch Inst Cardiol Mex 1997; 67: 101-105.
Carroza J, Kuntz R, Levine M, Pomerantz R, Fishman R et al. Angiographic and clinical outcome of intracoronary stening: Immediate and long term results from a large single center experience. J Am Coll Cardiol 1992: 20; 238-237.
Agrawal S, Ho D, Liu M. Predictors of thrombotic complications after placement of flexible coil stent. Am J Cardiol 1994; 73: 1216-1219.
Metz D, Urban P, Camenzid E, Chatelain P, Meier BN. Predicting. Ischemic complications after bailout stening following failed coronary angioplasty. Am J Cardiol 1994; 74: 271-274.
Morice M. Advances in post stening medications protocol. J Inv Cardiol 1995; 7: 32A-35A.
Hayde M, Erbel R, Issa H. Subacute trombotic complication after intracoronary implantation of Palmaz-Schatz stents. Am Heart J 1993; 126: 15-22.
Liu M, Voohees W, Agrawal S, Dean L, Roubin G. Stratification of the risk of thrombosis after intracoronary stening for threatened or acute closure complicating coronary balloon angioplasty. Am Heart J 1995; 130: 8-13.
Holmes D, Garrat K, Schwartz R. Timing of stent occlusion. Thrombosis after stent placement. J Am Coll Cardiol 1994; 23: 70A.
Bartorelli A, Montorsi P, Ravagnani P, Galli S, Squadroni L. Failure of fluoroscopy and success of intravascular ultrasound to locate an intracoronary embolized Palmaz-Schatz stent. J Invas Cardiol 1997; 9: 25-29.
Veldbuijzen F, Bonnier H, Michels R, El Gamal M, Van Gelder B. Retrieval of undeployed stent from the right coronary: Report of two cases. Cathet Cardiovasc Diagn 1993; 30: 245-248.
Pan M, Medina A, Romero M, De Lazo J, Hernandez E et al. Peripheral stent recovery after failed intracoronary delivery. Cathet Cardiovasc Diagn 1992; 27: 230-232.
Eeckhout E, Stauffer J, Goy J. Retrieval of a migrated coronary stent by means of an alligator forceps catheter. Cathet Cardiovasc Diagn 1993; 30: 166-168.
Foster K. Garrat K, Higano D. Retrieval techniques for managing flexible intracoronary stent misplacement. Cathet Cardiovasc Diagn 1993; 30: 63-66.
Eisenhauer A, Piemonte T, Gosman D, Ahmemnd L. Extraction fully deployed coronary stents. Cathet Cardiovasc Diagn 1996; 38: 393-401.
Rozenman Y, Burstein M, Hasin Y, Gotsman. Retrieval of occluding unexpanded Palmaz-Schatz stent from a saphenous, aorto-coronary vein graft. Cathet Cardiovasc Diagn 1995; 34: 159-161.
Berder V, Bedosa M, Gras D, Paillard F, Le Breton H, Pony J. Retrieval of lost coronary stent from the descending aorta using a PTCA balloon and biopsy forceps. Cathet Cardiovasc Diagn 1993; 28: 351-353.
Cishek M, Laslett L, Gershony G. Balloon catheter retrieval of dislodged artery stents. A novel technique Cathet Cardiovasc Diagn 1995; 34: 350-352.